Hi,
I'm stupid. I forget to update etc/graphite/storage-schemas.conf and
etc/graphite/storage-aggregation.conf.
I deleted all whisper databases and hopefully it will be much better now.
Mat
-----Original Message-----
From: JABUREK Martin
Sent: Tuesday, March 25, 2014 3:55 PM
To: 'John-Magne Bredal'; Morten Brekkevold
Cc: nav-users-***@public.gmane.org
Subject: RE: New to nav system
Hi,
Regarding the bug - I'm using 4.0b5 right now. Is the patch also applicable
for this version?
Restarting ipdevpoll does help, but not for the first time. I had to restart
it repeatadly (I did it due to other errors and then I mention, that it
corrected it)
Regarding the graphs I think there is some problem with graphing/storing
data?
I attached three pictures:
Ten correct.png ... correct graph from rrdtools
Ten graphite.png ... graph collected from graphite web interface
Ten nav.png ... graph collected from nav interface
It seems to me, that graphite stores too few datapoints, I tried to dump raw
data and I get this:
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:16:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:17:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:18:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25
09:19:00,6302589367015099.0
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:20:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:21:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:22:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25
09:23:00,6302603784021890.0
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:24:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:25:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:26:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:27:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25
09:28:00,6302617817392692.0
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:29:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:30:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:31:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:32:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:33:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25
09:34:00,6302631305894654.0
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:35:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:36:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:37:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25
09:38:00,6302639660718015.0
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:39:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:40:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:41:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:42:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25
09:43:00,6302653053594991.0
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:44:00,
nav.devices.DEVICE.ports.Te1_1.ifInOctets,2014-03-25 09:45:00,
Shouldn't I set up scheme for carbon database to await only 5 min
collections?
It seems to me, that after applying derivative function it show nothing due
to
empty datapoints.
Mat
-----Original Message-----
From: John-Magne Bredal [mailto:john.m.bredal-***@public.gmane.org]
Sent: Monday, March 24, 2014 2:36 PM
To: JABUREK Martin; Morten Brekkevold
Cc: nav-users-***@public.gmane.org
Subject: Re: New to nav system
Post by M***@public.gmane.orgI modified the unknown OIDs and now I am able to collect information
from boxes.
Great!
Post by M***@public.gmane.org- graphs showing throughput - there are only empty graphs on port info tabs.
I think that backend should be fine, because I can see some graphs
(for example SystemMetrics/CPU are all fine) Maybe it is related to a
fetch error from statistics pane. (see screenshot)
See below.
Post by M***@public.gmane.org2014-03-24 04:59:09,673 [WARNING plugins.dnsname.dnsname] [inventory
IP2] Box dnsname has changed from u 'IP2' to 'DNS2'
When I edit device it gets the right name, but it keep reporting only
IP. This started when I added unknown device and now I corrected it.
So I have other devices with right DNS names as sysnames.
We think this may be related to this bug:
https://bugs.launchpad.net/nav/+bug/1292513 . This has been fixed and will
be
part of the next release.
The port statistics are probably being stored using the IP-address not the
DNS
name of the IP Device. You can verify this by browsing the Graphite Web
interface and see which nodes are present under nav.devices.
Try restarting ipdevpoll. This may fix your current problem.
Post by M***@public.gmane.org- how can I change the look of graphs? I'm getting black backgrounded
graphs which are really ugly on white background.
In the graphite configuration directory (perhaps /opt/graphite/conf), copy
the
file graphTemplates.conf.example to graphTemplates.conf. Then edit it and
add
the following:
[nav]
background = white
foreground = black
Post by M***@public.gmane.orgThe work done is really amazing. I look forward when I have it finally
fully up.
Thank you! :)
--
John-Magne Bredal
UNINETT AS